Diagnostics (Offline OP’s)
The Diagnostics page allows for Advanced diagnostic actions and to view a list of alarms
(if any) for the OP. For OP’s that are offline, the available options are as follows:
Check Online: rechecks status to see if the OP is online
Reboot OP: reboots the physical OP hardware (only applicable if the Neuron is
communicating but the DSP is not)
Delete OP: deletes the record of the OP from the app.